Advance

PDF print version of this specification : A4 or Letter

The Universal Telecomms Adapter is an intelligent I/O adapter that uses a Motorola PowerQUICC II Integrated PowerPC Microprocessor as communication controller and offers various E1/T1, E3/T3, Fast Ethernet, ATM and serial I/O options.

The adapter is available in the following industry standard compliant formfactors :

Features

Specifications

Bus Interface

32-bit, 33/66 MHz
Electrically : PCI Rev.2.2, 3,3 V signalling

I/O Addresses

Automatically assigned to the slot by PCI Rev. 2.2 Plug-and-Play

EEPROM

EEPROM for board ID (Plug-and-Play) and configuration options

Interrupts

PCI INT A

DMA

Automatic depending on PCI slot

I/O Options

Front Panel or rear connector I/O options with various rear connector PMC Jn4 pin assignments

CPU

Motorola PowerQUICC II Integrated PowerPC Microprocessor

Power
(Preliminary)

3,3 V at 1,4 A

12 V at 1 mA

Software Drivers

Various software drivers offered including for VxWorks and Linux operating Systems as standard; others are costed options

 

Reliability
MTBF
(Preliminary)

Figures according to MIL-HDBK-217F, Parts Count Method

Ground, Mobile
Naval, Sheltered
Airborne, Inhabited Cargo  
Ta = 45 C
Ta = 40 C
Ta = 55 C
23 000 hrs
37 000 hrs
28 000 hrs

 

Characteristics

Formfactor

Dimensions

Mass

PMC (IEEE Std 1386.1-2001)

149,00 mm x 74,00 mm, conforming to CMC envelope

< 100 g

CCPMC (ANSI/VITA 20-2001)

143,65 mm x 74,00 mm, conforming to VITA 20 envelope

80 g +/- 5 g

PCI-104 (PCI-104 v2.0)

95,89 mm x 90,17 mm x 23,80 mm

90 g +/- 5 g

PCI (PCI Local Bus Specification Rev.2.3)

160,12 mm x 106,62 mm

120 g +/- 5 g

    

Environmental Specifications

 

Commercial Grade

Industrial Grade

Ruggedised/Conduction-Cooled Grade

Temperature
- Operating
- Storage

 
   0 C to +55 C
-40 C to +85 C


-15 C to +75 C
-40 C to +85 C


-40 C to +  85 C
-55 C to +125 C

Humidity

0% to 90%

0% to 95%

0% to 95%

Shock

N/A

30 g peak for 11 ms

40 g peak for 11 ms

Vibration
- Sine
- Random


2 g (peak) 10 Hz to 100 Hz
0,04 g²/Hz at 15 Hz to 2 kHz


10 g (peak) 5 Hz to 2 kHz
0,1 g²/Hz at 15 Hz to 2 kHz


10 g (peak) 5 Hz to 2 kHz
0,1 g²/Hz at 15 Hz to  2 kHz

 


CH8PS007 Rev.2  2010-06-06
CCII Systems (Pty) Ltd • P.O. Box 171 • Rondebosch 7701 • South Africa 